Supplementary corrosion inhibitor - open or closed cooling systems is an innovative, supplementary corrosion inhibitor developed specifically for use in open or closed cooling systems. In particular, RXSOL-40-4028 creates an insoluble polymeric surface complex on copper and its alloys, and also reacts with copper in solution.also works synergistically with other inhibitors to effectively control the corrosion of steel and aluminium in the system. 1) Corrosion Inhibitor Nitrite based for CLOSED LOOP: RXSOL-40-4023 is a high performance nitrite based closed circuit inhibitor.Nitrite based Corrosion Inhibitor for Water and Glycol Brine system is a multimetal corrosion inhibitor based on nitrate and othe organic compounds with special yellow metal corrosion inhibitor and antiscaling chemical that helps to prevent scale deposition or also removes adhering loose scale deposits from the heat transfer fluid system.The disadvantages of not treating the closed circuit water can be equally troubling for the system operator:- 1. Leakage in PHE and AHU due to corrosion 2. Plugging and clogging of tubes and reduced flow rate 3. REduced heat transfer 4. Need of regular descalling that incurs shutdowns, loss of labor and time 5. Fouling of brine of chiller waterChemical tratment removes dissolved oxygen that cause oxidation of metal to metal oxide i.e., Iron Oxygen = Iron Oxide (Rust)The chemical also contains a specific inhibitor to protect copper from corrosion and removes/prevents any sort of scale formation in the system. Part No.: RXSOL-40-4023-025 .2)Corrosion inhibitor Low nitrite / molybdate for closed circuits : RXSOL-40-4019 is a blend of superior quality low nitrite/molybdate based water treatment product developed specifically for closed circuit systems.RXSOL-40-4019 also contains isothiazoline. Part No.: RXSOL-40-4019-025 .3) Corrosion inhibitor, closed cooling systems - molybdate/phosphonat :

RXSOL-40-4018 is a superior molybdate/phosphonate based corrosion inhibitor developed for use in closed cooling water systems. RXSOL-40-4018 prevents corrosion and deposits in closed and aerated cooling water systems. RXSOL-40-4018 contains inhibitors for steel, copper and copper alloys in combination with dispersants. RXSOL-40-4018 keeps the surface of the cooling systems clean and provides thus the basis for the formation of an effective corrosion protection film. RXSOL-40-4018 is mainly applied in secondary cooling water systems of power plants, in the cooling systems of blast furnaces, in systems for cooling the molds in continuous casting mills and in hot and cold water systems in the chemical industry. The program should be used with soft water, to avoid calcium phosphate deposition when the water losses are important.

Ingredient: Metal Pretreatment Filming Agent, Film Settlement Agent, Surface Activating Agent, Sodium Molybdate, Organophosphorus and etc. Corrosion Rate: ≤0.125mm/year (Steel) Scale Formation Rate: ≤0.2mm/year . Part No.: RXSOL-40-4018-025.

  • Product Details
  • Brand :
  • Place of Origin : UAE
  • FOB Price : On Request
  • Minimum Order Quantity : 210Ltr
  • Supply Ability :
  • Packaging & Delivery
  • Packaging Detail : Packaging Details: Packing 5, 10, 25 , 210 4) Corrosion Inhibitor Nitrite - Phosphonate for CLOSED LOOP :It is a high performance nitrite based closed circuit inhibitor with phosphonate with unique formulation with ferrous & Non ferrous corrosion inhibitors, antiscalants , dispersant and buffer solution of non carbonate. Usefull for use in high or low temperature closed cooling water systems for the prevention of corrosion and scale formation in internal combustion engines, compressors, chiller system and DG sets. Protects all metals including cast iron, mild steels and copper. Recommended ppm levels are easily controlled by standered RXSOL test kit Nitrite / Chloride. Part No.:RXSOL-40-4013-020.5) scale corrosion inhibitor Open - closed cooling systems:RXSOL-40-RXSOL-40-4022 is a versatile molybdate-organophosphonate blend of scale and corrosion inhibitors for open recirculating cooling water systems. RXSOL-40-4022 is designed for syste
  • Delivery Detail :
  • Minimum Order Quantity: 5 Litre
  • Port of Dispatch: INDIA, Middle EAST
  • Production Capacity: 10 Mt / Day
  • Delivery Time: 1
Not Given